Product
Range
50 kVA to 5000 kVA, 11 kV & 33 kV Class
suitable for Indoor applications with off
circuit tap links, off circuit tap switch,
on load tap changer (Indigenous & Imported).
Standards
The Dry Type transformer are manufactured to
comply with National International Standards
BIS, IS 11171, IEC 76.
Quality
MUSKAAN’S products are certified for
ISO 9001 : 2000 by NABCB. MPIL has set up a
complete quality management system to offer
the best customer satisfaction.
Description
MPIL
manufacture Ventilated Dry Type Transformer
are totally maintenance free and safe from
fire as material used are metals, ceramics,
fiberglass and resin It is environment
friendly as there is no oil, hence handing
becomes easier and there are no chances of
spillages and leakages and there is minimal
non toxic smoke in case of fire.
MPIL offers Ventilated Dry Type Transformers
with class H/E insulation which can bear
heat upto 180/220 degree C and can be used
in humid and chemically polluted atmosphere.
Winding
LV & HV Winding are done in dust free air
conditioned winding shops. Rectangular
copper strips are used for LV winding
insulated with Nomex while HV winding are of
copper wire insulated with Nomex or suitable
material for temperature rise if wrapping is
not possible due to small diameter.
Testing
All transformers are tested for routine
test. MPIL has in-house facilities for
conducting all routine tests as per IEC &
IS.
Advantages
|
|
- High level of safety
- No flammable liquids
- No pollution from leaks solution
- No toxic off-gasses
- Can be placed close to the load
- More efficient
- Increased emergency overload
capability
- Improved reliability
- Low Noise and low maintenance
- Easy to repair (open coils)
|
Routine
Tests |
|
- Measurement of Winding Resistance
- Measurement of Voltage / Turns Ratio
- Measurement of Impedance Voltage /
Short Circuit
- Impedance & Load Loss
- Measurement of No Load Loss & No
Load Current
- Measurement of Insulation Resistance
- Di-Electric Tests
|
|
Environmental Impact Operation Aspects |
|
|
Warranty |
MUSKAAN’S VDT transformer are
guaranteed for satisfactory performance for
a period of 2 years from the date of
dispatch. Any part found defective during
this period, as a consequence of bad design,
manufacturing or workmanship should be
repaired free of cost by us within mutually
agreed schedule.
Warranty for 2 years on active part only.
|
Specification for MUSKAAN'S Dry Type
Transformers |
MPIL makes Indoor / Outdoor, 3 phase, 50/60
Hz, vaccum impregnated, AN/FA cooled, step
up/step down, double wound with Cu conductor
transformer from 50 kVA to 5000 kVA upto 33
kV class with H/E class insulation and
designed to withstand short circuit, &
impulse test in accordance to IEC / IS. |
|
Parameters |
VDT |
Cast Resin |
Conductor Insulation |
Nomex |
Non
woven polyester |
Thermal Rating |
F
or H/C |
F/B
or F |
Process |
Conventional Winding |
Cast Mold Assembly |
|
Assembly |
|
Impregnation |
Vacuum pressure |
Vacuum casting |
|
impregnation |
|
Repair |
Possible |
Not
Possible |
Cracking |
Not
Possible |
Possible |
Overloading |
High Over load margin |
No
Over load margin |
Environment |
Can
be easily |
Large amount of resin
|
concern |
disposed of |
to
be disposed of |
Safety |
No
toxic off gases, |
Emission of toxic gases |
|
no
melting |
|
Partial Discharge |
Free of partial |
Partial Discharge is possible
|
|
discharge |
due
to high probability of
|
|
|
bubbles formation during casting
|
|
|